8AM - 5PM EST 1-888-SHIVELY Contact

2600 Bandpass Filter Series (Model 2606)

Power levels up to 5 kW
Interdigital 6” design with 3 or 4 poles
Small design with same performance as resonant cavity design.
Input / Output – 1-5/8″ EIA

Options:
– Feedback Loops
– Forced Air Blowers
– Adapters for input/output

SKU: 2606

Description

Power levels up to 5 kW
Interdigital 6” design with 3 or 4 poles
Small design with same performance as resonant cavity design.
Input / Output – 1-5/8″ EIA

Options:
– Feedback Loops
– Forced Air Blowers
– Adapters for input/output

Reviews

There are no reviews yet.

Be the first to review “2600 Bandpass Filter Series (Model 2606)”

Your email address will not be published.

This site uses Akismet to reduce spam. Learn how your comment data is processed.

3 Pole
4 Pole

Typical Electrical Preformance

3 Pole Specifications

Performance SpecificationsModel 2606-3AModel 2606-3B
Maximum Input Power5 kW8 kW
CoolingConvectionForced Air
Input1-5/8" EIA
Output1-5/8" EIA
Shipping Weight175 lbs (89 kg)180 lbs (91 kg)
TypeInterdigital
Cavity Size6"
No. of Poles3
Typical VSWR
(deviation from
center frequency)

at F0< 1.05:1
at ± 200 kHz:< 1.10:1
Typical Insertion Loss< 0.40 dB
Typical frequency response
(deviation from
center frequency)

at ± 100 kHz:-0.04 dB
at ± 150 kHz:-0.08 dB
at ± 200 kHz:-0.10 dB
Typical group delay
(deviation from
center frequency)

at ± 100 kHz:20 nsec
at ± 150 kHz:50 nsec
at ± 200 kHz:100 nsec
Typical bandwidth±200 kHz

Dimensions
Shipping Weight: 175 lbs (80 kg)
{2606-3_Dim.jpg}

Typical Electrical Preformance

4 Pole Specifications

Performance SpecificationsModel 2606-4AModel 2606-4B
Maximum Input Power5 kW8 kW
CoolingConvectionForced Air
Input1 5/8" EIA
Output1 5/8" EIA
Shipping Weight195 lbs (89 kg)200 lbs (91 kg)
TypeInterdigital
Cavity Size6"
No. of Poles4
Typical VSWR
(deviation from
center frequency)

at ± 100 kHz:< 1.06:1
at ± 150 kHz:< 1.04:1
at ± 200 kHz:< 1.10:1
Typical Insertion Loss< 0.70 dB
Typical frequency response
(deviation from
center frequency)

at ± 100 kHz:-0.01 dB
at ± 150 kHz:-0.02 dB
at ± 200 kHz:-0.05 dB
Typical group delay
(deviation from
center frequency)

at ± 100 kHz:25 nsec
at ± 150 kHz:50 nsec
at ± 200 kHz:150 nsec
Typical bandwidth±200 kHz

Dimensions
Shipping Weight: 195 lbs (89 kg)
{2606-4_Dim.jpg}

SKU: 2606 CATEGORY: TAGS: