Description
Power levels up to 10 kW
12” design with 2, 3 or 4 poles
Small design with same performance as resonant cavity design.
Input – 1 5/8″ EIA
Output – 1 5/8″ EIA
Options:
– Feedback Loops
– Forced Air Blowers
Power levels up to 10 kW
12” design with 2, 3 or 4 poles
Small design with same performance as resonant cavity design.
Input – 1 5/8″ EIA
Output – 1 5/8″ EIA
Options:
– Feedback Loops
– Forced Air Blowers
Power levels up to 10 kW
12” design with 2, 3 or 4 poles
Small design with same performance as resonant cavity design.
Input – 1 5/8″ EIA
Output – 1 5/8″ EIA
Options:
– Feedback Loops
– Forced Air Blowers
Typical Electrical Performance
2 Pole Specifications
Performance Specifications | Model 2712-2A | Model 2712-2B | |
Maximum Input Power | 10 kW | 15 kW | |
Cooling | Convection | Forced Air | |
Input | 1-5/8" EIA | ||
Output | 1-5/8" EIA | ||
Shipping Weight | 160 lbs (73 kg) | 180 lbs (82 kg) | |
Type | Resonant Cavity | ||
Cavity Size | 12" | ||
No. of Poles | 2 | ||
Typical VSWR (deviation from center frequency) | at ± 100 kHz: | < 1.05:1 | |
at ± 200 kHz: | < 1.10:1 | ||
Typical Insertion Loss | < 0.15 dB | ||
Typical frequency response (deviation from center frequency) | at ± 100 kHz: | -0.04 dB | |
at ± 150 kHz: | -0.08 dB | ||
at ± 200 kHz: | -0.10 dB | ||
Typical group delay (deviation from center frequency) | at ± 100 kHz: | 20 nsec | |
at ± 150 kHz: | 40 nsec | ||
at ± 200 kHz: | 150 nsec | ||
Typical bandwidth | ±200 kHz |
Dimensions
2712-2
Typical Electrical Performance
3 Pole Specifications
Performance Specifications | Model 2712-3A | Model 2712-3B | |
Maximum Input Power | 10 kW | 15 kW | |
Cooling | Convection | Forced Air | |
Input | 1-5/8" EIA | ||
Output | 1-5/8" EIA | ||
Shipping Weight | 230 lbs (105 kg) | 250 lbs (114 kg) | |
Type | Resonant Cavity | ||
Cavity Size | 12" | ||
No. of Poles | 3 | ||
Typical VSWR (deviation from center frequency) | at ± 100 kHz: | < 1.05:1 | |
at ± 200 kHz: | < 1.10:1 | ||
Typical Insertion Loss | < 0.23 dB | ||
Typical frequency response (deviation from center frequency) | at ± 100 kHz: | -0.04 dB | |
at ± 150 kHz: | -0.08 dB | ||
at ± 200 kHz: | -0.10 dB | ||
Typical group delay (deviation from center frequency) | at ± 100 kHz: | 20 nsec | |
at ± 150 kHz: | 40 nsec | ||
at ± 200 kHz: | 150 nsec | ||
Typical bandwidth | ±200 kHz |
Dimensions
2712-3
Typical Electrical Performance
4 Pole Specifications
Performance Specifications | Model 2712-4A | Model 2712-4B | |
Maximum Input Power | 10 kW | 15 kW | |
Cooling | Convection | Forced Air | |
Input | 1 5/8" EIA | ||
Output | 1 5/8" EIA | ||
Shipping Weight | 270 lb (123 kg) | 300 lbs (136 kg) | |
Type | Resonant Cavity | ||
Cavity Size | 12" | ||
No. of Poles | 4 | ||
Typical VSWR (deviation from center frequency) | at ± 100 kHz: | < 1.06:1 | |
at ± 200 kHz: | < 1.10:1 | ||
Typical Insertion Loss | ~ -0.30 dB | ||
Typical frequency response (deviation from center frequency) | at ± 100 kHz: | -0.01 dB | |
at ± 150 kHz: | -0.02 dB | ||
at ± 200 kHz: | -0.05 dB | ||
Typical group delay (deviation from center frequency) | at ± 100 kHz: | 25 nsec | |
at ± 150 kHz: | 50 nsec | ||
at ± 200 kHz: | 150 nsec | ||
Typical bandwidth | ±200 kHz |
Dimensions
2712-4
Reviews
There are no reviews yet.