No Factory personnel needed for installation. Please read the installation manual in full before assembly on site.
Dimensional Drawing
SLV-2R
Installation Manuals
im-SLV 1-6
- Must be mounted on a metal pipe or tower leg 1-1/2″ (38mm) to 3-1/2” (90mm) outside diameter. Pipe not supplied by Shively; requires 5’, 1.5m of clear space on pipe above and below antenna.
Model SLV Antenna Fullwave Weight & Wind Load
Tower Space Full-wave Spaced
No. of elements | Tower Space Required |
SLV-1 (1 element) | 0.9 m (2 ft 11 in) |
SLV-2 (2 elements) | 3.9 m (12 ft 10 in) |
SLV-4 (4 elements) | 9.9 m (32 ft 6 in) |
SLV-6 (6 elements) | 16 m (52 ft 6 in) |
| |
Windload Full-wave Spaced
No. of elements | Weight without ice | Windload without Ice |
| N | lb | EPAN | EPAT |
m2 | ft2 | m2 | ft2 |
SLV-1 (1 element) | 67 | 15 | 0.2 | 1.7 | 0.1 | 1.2 |
SLV-2 (2 elements) | 156 | 35 | 0.3 | 3.3 | 0.2 | 2.4 |
SLV-4 (4 elements) | 334 | 75 | 0.6 | 6.6 | 0.4 | 4.8 |
SLV-6 (6 elements) | 467 | 105 | 0.9 | 9.9 | 0.6 | 7.2 |
| | | | | | |
No. of elements | Weight with 13 mm (1/2 in) ice | Windload with 13 mm (1/2") ice |
| N | lb | EPAN | EPAT |
m2 | ft2 | m2 | ft2 |
SLV-1 (1 element) | 138 | 31 | 0.3 | 2.7 | 0.2 | 2 |
SLV-2 (2 elements) | 294 | 66 | 0.5 | 5.4 | 0.4 | 4.1 |
SLV-4 (4 elements) | 587 | 132 | 1.0 | 10.8 | 0.8 | 8.2 |
SLV-6 (6 elements) | 881 | 198 | 1.5 | 16.2 | 1.2 | 12.3 |
| | | | | | |
No. of elements | Weight with 51 mm (2 in) ice | Windload with 51 mm (2 in) ice |
| N | lb | EPAN | EPAT |
m2 | ft2 | m2 | ft2 |
SLV-1 (1 element) | 596 | 134 | 0.5 | 4.9 | 0.4 | 4 |
SLV-2 (2 elements) | 1219 | 274 | 0.9 | 9.7 | 0.7 | 7.9 |
SLV-4 (4 elements) | 2438 | 548 | 1.8 | 19.4 | 1.5 | 15.8 |
SLV-6 (6 elements) | 3656 | 822 | 2.7 | 29.1 | 2.1 | 23.7 |
| | | | | | |
No. of elements | Weight with radome and without ice | Windload with radome and without Ice |
| N | lb | EPAN | EPAT |
m2 | ft2 | m2 | ft2 |
SLV-1 (1 element) | 173 | 39 | 0.9 | 9.7 | 0.7 | 7.4 |
SLV-2 (2 elements) | 369 | 83 | 1.8 | 19.3 | 1.4 | 14.8 |
SLV-4 (4 elements) | 761 | 171 | 3.6 | 38.6 | 2.7 | 29.6 |
SLV-6 (6 elements) | 1108 | 249 | 5.4 | 57.9 | 4.2 | 44.4 |
| | | | | | |
No. of elements | Weight with radome with 13 mm (1/2 in) ice | Windload with radome with 13 mm (1/2 in) ice |
| N | lb | EPAN | EPAT |
m2 | ft2 | m2 | ft2 |
SLV-1 (1 element) | 1118 | 251.3 | 0.9 | 10.0 | 0.7 | 7.8 |
SLV-2 (2 elements) | 2293 | 515.7 | 1.9 | 20.0 | 1.4 | 15.5 |
SLV-4 (4 elements) | 4588 | 1031.5 | 3.7 | 40.0 | 2.9 | 31.0 |
SLV-6 (6 elements) | 6881 | 1547 | 5.7 | 60 | 4.2 | 46.5 |
| | | | | | |
No. of elements | Weight with radome and 51 mm (2 in) ice | Windload with radome and 51 mm (2 in) ice |
| N | lb | EPAN | EPAT |
m2 | ft2 | m2 | ft2 |
SLV-1 (1 element) | 3460 | 778 | 1.0 | 10.6 | 0.8 | 8.4 |
SLV-2 (2 elements) | 6970 | 1567 | 2.0 | 21.3 | 1.6 | 16.8 |
SLV-4 (4 elements) | 13940 | 3134 | 4.0 | 42.6 | 3.1 | 33.6 |
SLV-6 (6 elements) | 20910 | 4701 | 6 | 63.9 | 4.8 | 50.4 |
| | | | | | |
Notes:
WINDLOAD TABLE(S)
1. Standard mounts are designed to fit customer-supplied 1-1/4″ ips (1.5″ OD) – 3″ pipe (3.5″ OD) pole or tower leg.
2. Windload and weight tabulations are estimates and assume 98 MHz. No values are included for mounts. The values for mounts, complex feed systems and directional arrays may significantly affect these estimates. Shielding due to the tower has not been accounted for. Please contact the factory for an estimate for a system to meet your specific requirements.
3. Antenna areas and weights calculated in accordance with TIA-222-G.
- EPAN – Effective projected area associated with the windward face normal to the azimuth of the antenna: EPAN = ∑(CaAA)N
- EPAT – Effective projected area associated with the windward face at the side of the antenna: EPAT=∑(CaAA)T
- Assumptions: Structure Class II; Exposure Category C; Topographic Category 1; Maximum basic windspeed 120 mph; with 1/2 inch radial ice, 40 mph.
4. Half-wave spacing and higher-power arrays are available as special configurations. Contact the factory.
5. System designed for maximum of 2″ factored radial ice (tis) at height using TIA-222-G specifications and maximum velocity pressure of 51.29 lbf/ft2 with no ice.
6. Ask for technical assistance at Shively if you are planning to mount antennas on AM towers or install them at altitudes over 3,000ft (915m) above mean sea level.